The access points that hotels fit in guest rooms sit flat on a wall and radiate into the room, not around the device. Plan them with a facing direction, not as circles, or the heatmap will promise coverage the guest room does not get.

Why wall-plate units are not circular

A ceiling access point has an antenna that radiates all the way round it. A wall-plate unit (the Ruckus H series, Aruba 500H and 600H, Cisco Catalyst 9105AXW, Meraki MR30H and MR36H, UniFi U6-IW, TP-Link Omada Wall models, Alcatel-Lucent Enterprise AP1201H and AP1301H, Zyxel WAX300H) is a flat unit built into a standard wall box. Its antennas sit in front of the wall, so most of the energy goes into the room and much less goes through or along the wall. Vendors describe this in different words, and they publish the actual shape only as azimuth and elevation plots in the datasheet. For ceiling units, which radiate around the device, read how ceiling access points radiate.

What the datasheets say

Vendor and modelsWhat the datasheet saysPublished gain
Cisco Catalyst 9105AXWIntegrated antennas that are directional in azimuth; radiation patterns in the installation guide3 dBi (2.4 GHz), 5 dBi (5 GHz)
Aruba AP-503H, AP-505H, AP-605HSemi-directional or directional antennas, optimized for vertical wall or desk mounted orientation; patterns plotted for the combined antennasPeak and combined average-pattern gain are both published, for example AP-503H 5.6 and 5.0 dBi at 5 GHz
Ruckus H350, H510, H550BeamFlex+ adaptive antenna with 16 patterns per band; the plots show one pattern and the wide composite footprint of all of themUp to 1 dBi
Meraki MR30H and MR36H, TP-Link EAP615-Wall and EAP655-Wall, UniFi U6-IW, ALE AP1201H and AP1301H, Zyxel WAX300HListed as internal or omnidirectional antennas on a flat wall-plate body; radiation plots in the datasheet or installation guide3 to 6.3 dBi depending on model and band

None of these datasheets gives the beamwidth or the front-to-back ratio as a number that can be read without measuring the plot, so Signal Plan models the shape (below) and takes gain and streams from the datasheet.

How Signal Plan models it

Each wall-plate model has a facing direction and a loss that grows with the angle off that direction. Directional units (Cisco 9105AXW, Aruba 500H and 600H) use a 110° half-power beamwidth and 15 dB front-to-back. Adaptive units (Ruckus H series) use 150° and 12 dB, because the composite footprint is wide. Flat wall-plate units that vendors list as omni use 140° and 12 dB. On the plan each unit shows its pattern as a lobe with an arrow for the facing direction and a bar for the wall it sits on. Add one by clicking next to a wall: it snaps to the wall and faces into the room. Turn it with the Turn buttons, the [ and ] keys, or by dragging its handle.

Planning rules for hotel rooms

Settings to try in the planner

Worked example: one wall-plate unit, six cases

Dashed circle: ceiling access point. Blue lobe: wall-plate.wallfacing

Take a flat wall-plate access point (140° half-power beamwidth, 12 dB front-to-back, the planner's class for units that vendors list as omni) at 20 dBm EIRP on its facing axis, 5 GHz, the planner's 8 dB link margin, a hotel path-loss exponent of 3.1 and a target of -67 dBm. The same unit reaches very different distances depending on where the guest is:

DirectionPattern lossReach at -67 dBmShare of the straight-out reach
Straight out of the wall (0°)0.0 dB10.7 m100%
45° off the facing direction0.9 dB10.0 m93%
At the half-power angle (70°)2.8 dB8.7 m81%
Along the wall (90°)12.3 dB4.3 m40%
Straight back, into the wall (180°)12.3 dB4.3 m40%
Straight back, through a 10 dB concrete wall12.3 dB1.8 m16%

A ceiling access point with the same power would reach about 10.7 m in every direction. The wall-plate reaches 10.7 m straight into the room but only about 4.3 m behind the wall before the wall itself is counted, and it hardly reaches the room behind a concrete wall at all. That is why one unit per room, facing into the room, works and why a unit placed on a party wall does not serve the room behind it. These are model values for planning; confirm them with an on-site survey.

Upload your floor plan and try it free: Open the Wi-Fi heatmap planner

Forecasts are planning estimates. Validate with an on-site survey before buying or installing equipment. See also the AP placement guide, the RSSI guide and planner pages by brand.

← Back to the planner · Guides · All brands · AP placement guide · RSSI guide · Articles · Pro · About · Methodology